PCD – Coupling/decoupling networks for high current DC lines up to 1400 V / 400A up to 6kV Surge testing
Standalone coupling/decoupling networks. According to IEC/EN 61000-4-5 the pulses are manually coupled via bridge elements with line to line (2 ohm/18 uF) or line to PE with (12 Ohm/ 9 uf).
PCD – Coupling/decoupling networks for high current DC lines up to 1500 V / 400A up to 8kV Burst testing
Standalone coupling/decoupling networks. According to IEC/EN 61000-4-4 the pulses are coupled via 33 nF capacitors to all lines DC+, DC- and to PE.
CCI PVKIT 1 – Calibration Kit for Capacitive Coupling Clamp verification
Calibration kit for capacitive coupling clamp as per IEC 61000-4-4 Ed.3. Extension for the PVF BKIT 1 for capacitive coupling clamp calibration with EFT/burst.
PVF BKIT 1 – Load resistors for EFT/burst verification
Calibration kit as per IEC 61000-4-4. Also used as per ISO 7637, Annex D.
IMN2 – Impedance Matching Network for Surge impulse Generators
The IMN2 replaces, at the HV-COM output, the surge generator’s external coupler. It is required as per IEC 61000-4-5 Ed.3 so that the pulse specifications can be accurately matched.
ITP- Immunity Test Probes
ITP is a tool being used for development test. It consists of a variety of electrical field probes. The probes allow to locate weak points within a system or on a PCB. The burst pulse is used to generate the disturbance signal
MS 100N – magnetic field coil for power-frequency and pulsed magnetic fields
The MS 100N is a 1m x 1m magnetic field coil as specified in IEC/EN 61000-4-8 and IEC/EN 61000-4-9. Its design allows easy moving of the coil. The field coil is adjustable in height and allows for 360degree rotation.
To generate power-frequency magnetic fields in the lower range the current transformer MFT 30 is used while high-field strength above 100 A/m up to 1000 A/m requires the MFT 100 current transformer.
MFT 30 – Current transformer for magnetic fields up to 30 A/m
MFT 100 – Current transformer for magnetic fields up to 1,000 A/m
SVP 1700 – Verification kit for Power Fail Simulators
According to EN/IEC 61000-4-11, IEC/EN 61000-4-34,
Built-in current probe 10 mV/A,
Built-in 5.4 kOhm resistor to discharge the storage capacitor,
Monitor output to measure the residual capacitor voltage (divider 100:1)
SVP CL100 – Load resistor for Power Fail Simulators verification
According to EN/IEC 61000-4-11, -29, -34
Low inductive 100 Ohm carbon load resistor
Forced air cooled with ventilators
230 VAC continuous, 400 VAC 30 minutes maximum
Auto switch off when cooling fails
TLT-8-690 (Balun)
Unbalanced / balanced transmission line transformer for line to line EFT / Burst tests. This is required as per ANSI/IEEE C37.90.