A major component in a SCANFLEX system are the optional I/O Modules.
These I/O modules are controlled independently from any other resources in the system through the SFX/LS interface. If the number of required SCANFLEX I/O Modules is very small (only 1 to 2 modules needed) the modules can be plugged directly onto the TAP-Transceiver, eliminating any additional cabling.
SCANFLEX I/O Modules are used to extend the performance and capabilities of the Boundary Scan system with additional test instruments and programming resources, highly modular and scalable to match any specific test/ISP application. Custom specific modifications of standard modules and development of custom modules are offered through GÖPEL electronic’s engineering services.
Alternatively, I/O modules can be put into SCANFLEX Carriers, connected to the Controller or the TAP Transceiver through a SFX/LS cable (0.5 m/1.5f t, 1 m/3 ft, 3 m/10 ft, or 5 m/15 ft). These carriers are built in a desktop box and available in different sizes to carry 5, 10 or 15 I/O modules.
Quick Enquiry
If you want to know more about JTAG/Boundary Scan I/O Modules
CION Modules are based on the CION™ interface chip, also developed by GOEPEL electronic, and can be serially accessed and controlled through a TAP. They are external boundary scan extensions of the units under test and can be used to test peripheral I/Os, connectors, backplanes, bases, etc.
Several modules of the same or different size can easily be cascaded to increase the number of channels. Currently, we are offering CION Modules in four different versions.
SCANFLEX I/O Modules are used to extend the performance and capabilities of the Boundary Scan system with additional test instruments and programming resources, highly modular and scalable to match any specific test/ISP application. Custom specific modifications of standard modules and development of custom modules are offered through GÖPEL electronic’s engineering services.
Alternatively, I/O modules can be put into SCANFLEX Carriers, connected to the Controller or the TAP Transceiver through a SFX/LS cable (0.5 m/1.5f t, 1 m/3 ft, 3 m/10 ft, or 5 m/15 ft). These carriers are built in a desktop box and available in different sizes to carry 5, 10 or 15 I/O modules.
Some examples of I/O modules:
Check our Product Overview in de “Datasheet Tab” for a complete overview of available modules. Additional modules are becoming continuously available.
In the range of the powerful JTAG/Boundary Scan Hardware Platform SCANFLEX II GÖPEL electronic has developed a new interface tester. The SCANFLEX II Interface Tester Master (SFX II ITM) enables you to significantly improve the test depth in the field of advanced bus interfaces.
SCANFLEX II Interface Tester Master (SFX II ITM)
The Interface Test Master has 8 independent and freely configurable ITMC slots for inserting ITM cards (ITMC). With the exchangeable ITM cards, you can adapt the module to your specific test scenario and test the performance of a wide range of interfaces – from simple variants such as RS232, I2C and SPI to more complex interfaces such as USB, LAN and media connections. The multi-core system’s performance enables parallel interface tests of up to 8 interfaces or DUTs. The architecture of the SFX II ITM/8 is optimized for direct installation in fixtures with easy signal feed and wiring. This also optimizes the connection to the DUT.
The SFX II ITM/8 is primarily controlled via LAN connection to the SFXII controller, alternatively via UART interface (RS232) or an IEEE1149.1 TAP connection. In addition to operation with SCANFLEX II the Interface Test Master can also be operated as a stand-alone unit. For this purpose it offers an integrated Web Service based on the Web Service Description Language (WSDL).
Developed to extend test coverage: • Providing IEEE1149.1 compatible control IF (cascadable) • Based on CION-LX devices + additional resources (except FXT-X90 ) • Assembled with standard 2,54 mm Pin header for easy access and wire wrap connection
Examples:
CION-LX Module™ FXT-96
3 CION-LX Devices 96 I/O Channels 24 Differential Channels 12 High Current Channels
CION-LX Module™ FXT-192
6 CION-LX Devices 192 I/O Channels 48 Differential Channels 24 High Current Channels
This website uses cookies to ensure you get the best experience on our website. AcceptRead More
Privacy & Cookies Policy
Privacy Overview
This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.