This 500 watt, 800MHz to 3.1GHz amplifier is supplied in a compact 10U package. With a minimum of 450 watts of linear power this amplifier is ideal for RF immunity testing to various industry standards such as IEC61000-4-3, MIL-STD 461, ISO11452 and RTCA DO160. Compatible with a wide range of available antenna such as the Teseq CBL or BHA range and test systems such as the Teseq NSG4070 and NSG 6000 these amplifiers can be easily built into integrated test systems. The touch screen colour display gives an immediate visual indication of forward and reverse power along with the current operating status of the amplifier and access to diagnostic information such as gate current and heatsink temperature.
Fan speed adjusts depending on heatsink temperature thus ensuring the minimum audio noise level possible in the operating environment. The inbuilt calibrated directional coupler provides a quick and easy way to monitor forward and reflected power with any power meter. Input over- drive protection prevents damage to the input devices due to accidental high input power. Multiple remote interfaces are available as standard including USB, GPIB, RS232 and Ethernet. Amplifier gain can be controlled either remotely through one of the available interfaces or via the front panel touch screen.
Parameter | Value |
---|---|
Frequency range (instantaneous) | 800 to 3100 MHz |
Rated output power | 500 W minimum |
Output power at 1 dB gain compression | 450 W minimum |
Small Signal Gain
Gain Control |
57 dB
0-30 dB in 255 Steps |
Harmonics at P1 dB | -20 dBc |
Power Supply Voltage | STAR or DELTA |
Power Supply Phases | 3 |