Search

EM Test CNV 504N5.1

Dedicated CDN for the coupling of slow damped oscillatory waves as per EN/IEC 61000-4-18

Coupling/decoupling networks for 4 signal/data lines

  • For slow damped oscillatory waves as per EN/IEC 61000-4-18
  • Coupling capacitor 0.5uF
  • Decoupling inductor 1.5 mH for 50 V AC/DC
  • Nominal line current 4A AC/DC
  • Source impedance 200 Ohm (100 + 100 Ohm)
  • max. 3kV peak for 100kHz and 1MHz damped oscillatory waves

Quick Enquiry

If you want to know more about EM Test CNV 504N5.1
Dedicated CDN for the coupling of slow damped oscillatory waves as per EN/IEC 61000-4-18

 

The CNV 504N5-series coupling/decoupling networks are used to apply slow damped oscillatory waves onto signal/data lines in accordance to EN/IEC 61000-4-18. A capacitance of 0.5uF is specified to couple the pulses on to the lines. Each line has a decoupling inductor of 1.5mH or 3.0 mH to protect the auxiliary equipment from being subjected to the test pulse. The disturbance signal used for this test is a damped oscillatory pulse with a frequency of 100kHz or 1MHz, being generated by the EM TEST OCS 500N6 or OCS 500N6F. The CNV 504N5 series supports voltages of up to 250V AC/DC and a current of up to 4A AC/DC.

  • IEC 61000-4-18

EM Test CNV 504N5.1 Datasheet