Search

Teseq NSG 4060A

Low frequency immunity test system

  • Signal generator and integrated power amplifier 15 Hz to 150 kHz
  • Meets IEC / EN 61000-4-16 in combination with NSG 4060-1
  • Meets IEC / EN 61000-4-19 in combination with CDND M316-2 for voltage and CT 419-5 for current testing
  • Meets IEC/EN 60255-26 Annex A in combination with CN 60255-26
  • Prepared test configurations for IEC / EN 61000-4-16 and IEC / EN 61000-4-19
  • 5.7” color display
  • Multiple EUT monitoring options

Quick Enquiry

If you want to know more about Teseq NSG 4060A

The NSG 4060 is an EMC immunity test system for the frequency range 15 Hz to 150 kHz. It consists of a sine wave generator, power amplifier, EUT monitoring interfaces and different coupling units depending on the application, i. e. NSG 4060-1 for testing IEC / EN 61000-4-16 including short duration disturbance tests for DC, AC from 162/3 Hz to 200 Hz and test levels up to 300 V. Voltage testing according IEC / EN 61000-4-19 requires the combination with CDND M316-2. It includes the differential mode coupling and decoupling and the required 10 Ω impedance of the disturbance source. Current testing according IEC / EN 61000-4-19, e.g. testing electricity meters, requires the combination with CT 419-5.
The powerful and easy to use firmware makes the NSG 4060A independent from an external PC and control software, however it can also be remote controlled for system operation. Part of NSG 4060’s delivery is an USB-to-serial / optical converter which offers potential free remote control.

Technical specifications NSG 4060A in combination with NSG 4060-1

Parameter Value
Application: IEC 61000-4-16 edition 2.0, EN 61000-4-16:1998 / FprA3:2015
Frequency range Short duration test 1 s: DC, 162/3 Hz to 200 Hz
Sweep and continuous test: 13 Hz to 150 kHz
Output voltage Short duration test 1 s: 0.1 Vrms to ≥300 Vrms (max. 2 A), 0.1 Vrms to 100 V DC
Sweep and continuous test: 0.1 Vrms to ≥30 Vrms
Phase synchronisation:
Harmonic distortion: Short duration test: <10%
Sweep and continuous test: <1%
Rise and fall time: DC output voltage at on / off switching between 1 to 5 μsbetween 1 to 5 μs
Output impedance: 50 Ω ±10%

Technical specifications NSG 4060A in combination with CDND M316-2

Parameter Value
Application: IEC 61000-4-19 edition 1.0, EN 61000-4-19:2015
Frequency range: 2 kHz to 150 kHz
Output voltage: 0.1 Vrms to ≥20 Vrms
Output impedance: 10 Ω ±30%
Harmonic distortion: <5%
Pulse modulation Modulation frequency range: 3 Hz to 10 kHz
Frequency resolution: 0.01 Hz
Duty cycle: 50%
Rise / fall time (10% / 90%): < 10 μs

Technical specifications NSG 4060A in combination with CT 419-5

Parameter Value
Application: IEC 61000-4-19 edition 1.0, EN 61000-4-19:2015
TR 50579:2012
Frequency range: 2 kHz to 150 kHz
Output current: 2 kHz to 30 kHz 0.1 A to ≥4 A
30 kHz to 150 kHz 0.1 A to ≥2 A
Harmonic distortion: <5%
Pulse modulation: Modulation frequency range: 3 Hz to 10 kHz
Frequency resolution: 0.01 Hz
Duty cycle: 50%
Rise / fall time (10% / 90%): < 10 μs
Output impedance:  1 Ω ±30%

General specifications NSG 4060A

Parameter Value
Display: 640 x 480, 5.7” color
Output connector: 4 mm safety banana
User port: D-Sub 15 pole with 4 TTL inputs and 4 TTL outputs
+12 V / 100 mA, -12 V / 100 mA, +5 V / 100 mA power supply
Monitoring input analog: BNC socket, 0-24 V Ri=>15 kΩ, 6 mV resolution
Monitoring digital input: BNC socket, 0 to 24 V via optical coupler Ri=1.5 k Ω, switching threshold approx. 2 to 3 V
Monitoring optical input: optical fiber, HP versatile link HFBR0501 series 40 kBd
Sensor input: ODU socket, 0 to 5 V Ri≥4 kΩ, 6 mV resolution
External modulation input: BNC socket (prepared only)
RS232: D-Sub 9 pole, up to 115200 Bd
RS232 optical: Connector 2 x HFBRx523 socket for 1 mm fiber optic cable with length between 5 m and 30 m with 115200 Bd, for other distances 38400 Bd, max. 50 m
Size (W x H x D): 45 cm (19“) x 15 cm (3HU) x 42.3 cm (with handle bar and foot)
Weight: approx. 15 kg
Cardboard box: 60 cm x 55 cm x 37 cm, weight of cardboard box approx. 2.3 kg (empty)

General specifications NSG 4060-1 Extension Unit

Parameter Value
Input / output connectors: 4 mm safety bananas
Size (W x H x D): 45 cm (19“) x 15 cm (3HU) x 37.5 cm
Weight: approx. 35 kg
Packing case: 66 cm x 55 cm x 32 cm, approx. 10 kg (empty)
  • IEC/EN 61000-4-16
  • IEC/EN 61000-4-19
  • IEC/EN 60255-26

Teseq NSG 4060 Datasheet