Search

EM Test PFS 200N Series

Power Fail simulator

Automotive Power Fail Simulator

Highlights

  • Standalone test generator for voltage dips and interruptions
  • Rise/fall time <1us
  • Electronic short-circuit protection
  • Rated voltage 80V DC
  • Front panel operation
  • Standard Test routines
  • USB and GPIB interfaces

Quick Enquiry

If you want to know more about EM Test PFS 200N Series
Power Fail simulator

EMTest PFS 200N – Automotive Power Fail Simulator For Voltage Dips and Interruptions

The PFS 200N Automotive Power Fail simulator is used to comply with standard requirements, mainly from vehicle manufacturers, to perform fast voltage dips ad drops (micro-interruptions). Some standards specify very fast rise and fall times below 1 microsecond an electronic switch.

  • BMW GS 95003-2
  • BMW GS 95024-2-1
  • Chrysler CS-11809 (2009)
  • Chrysler CS-11979
  • Chrysler PF-9326
  • Cummins 14269 (982022-026)
  • DaimlerChrysler DC-10615
  • DaimlerChrysler DC-10842
  • DaimlerChrysler PF-10541
  • Fiat 9.90110
  • Ford EMC-CS-2009.1
  • Ford ES-XW7T-1A278-AB
  • Ford ES-XW7T-1A278-AC
  • Ford WDR 00.00EA
  • Freightliner 49-00085
  • GMW 3172
  • Hyundai/Kia ES 95400-10, Rev. D
  • Hyundai/Kia ES 96100-02 (2006)
  • Hyundai ES 39110-00
  • ISO 21848:2005
  • ISO 16750-2
  • Iveco 16-2103 Rev.15 (2010)
  • Jaguar EMC-CS-2010JLR V1.1 (2011-01)
  • JASO D001-94
  • Kia/Hyundai ES 95400-10
  • Mack Trucks 606GS15
  • Mazda MES PW 67600
  • MBN 10615
  • MBN LV 124-1
  • Mitsubishi ES-X82010
  • Nissan 28401 NDS 02
  • OEM LV 124
  • Porsche
  • PSA B21 7090
  • PSA B21 7110
  • Renault 36.00.808/–D
  • Renault 36.00.808/–E
  • Renault 36.00.808/–F
  • Renault 36.00.808/–G
  • Renault 36.00.808/–H
  • Renault 36.00.808/–J
  • Renault 36.00.808/–K
  • SAE J2628 (2007)
  • Tata TST/TS/WI/257
  • Toyota TSC3500G
  • Toyota TSC3590G
  • Toyota TSC6203G
  • Toyota TSC7203G
  • Volvo EMC Requirements (1998)
  • Volvo EMC Requirements (2002)
  • Volvo STD 515-0003
  • VW 80000

The PFS 200N is a standalone tester providing an electronic switch to perform voltage dips and drops (micro-interruptions) with fast rise and fall times of 1 microsecond. For voltage dips two DC voltage supplies are required while for for voltage drops (micro-interruptions) only one DC voltage supply is needed. The PFS 200N has the ability to control one external DC voltage source by means of an analog DC signal. The PFS 200N can also be easily integrated into a complete test set-up.
Operation is possible both manually and by software via USB or GPIB. Fail inputs allow to control an ongoing test sequence based on the status of the DUT. Pre-programmed Standard Test routines allow highest user convenience. Still the PFS 200N offers the Quick Start test routine where parameters can be changed on-line during a test to evaluate the susceptibility level of an individual DUT.

iso.control Software for control and documentation

Outstanding user convenience, clearly structured windows and operation features and the EM TEST standards library along with the flexibility to generate user specific test sequences very easily are the main features of iso.control software. The software is automatically configured according to the connected EM TEST generators. iso.control software covers international/national standards and most of the manufacturer standards and is continuously updated. Extensive reporting capabilities help the user to create test reports that meet international requirements.
iso.control is supported by Windows 2000, Windows XP, Windows Vista, Windows 7 and Windows 8. Remote control is achieved either via USB or GPIB. iso.control supports a wide range of GPIB cards of National Instruments.

RDS 200N – External controlled DC Power Supply

In order to generate any voltages between the level of the battery supply and zero for voltage drops (micro-interruption) tests a controlled DC supply is needed. The RDS 200N perfectly fits these requirements and is controlled by the analog DC output signal of the PFS 200N.
The RDS 200N is usually connected to the PF2 input of the PFS 200N.

PFS 200N  Datasheet