Teseq TEM Horn

600 MHz – 6 GHz

TEM Horn for IEC / EN 61000-4-39

  • TEM horn for IEC / EN 61000-4-39
  • One TEM horn for the frequency range 600 MHz to 6 GHz
  • Extendable with matching networks for the TETRA 400 and GMRS 460 / FRS 460 applications
  • High efficiency
  • For level setting @ 10cm please use TEM probe

Quick Enquiry

If you want to know more about Teseq TEM Horn
600 MHz – 6 GHz

The basic EMC publication IEC / EN 61000-4-39 „Electromagnetic Compatibility (EMC) – Part 4-39: Testing and measurement techniques – Radiated fields in close proximity – Immunity test” describes test methods unique to the situation in which the transmitter is used in close proximity to the EUT. The Teseq TEM horn generates homogeneous fields in the large frequency range from 600 MHz to 6 GHz. Two optional available matching network adapters allow to extend the frequency range for the TETRA 400 and GMRS 460 / FRS 460 applications. Using the adapters means one TEM horn for all the bands.
The mounting fixture allows easy adjustment for vertical, horizontal polarizations, and has a standard camera thread (1/4” X 20) hole that allows fitting to many support structures including all Teseq tripods (note Teseq adapters may be required). The combination TEM horn with dipole tube BAA 6001 is recommended for mounting the TEM horn to ∅ 22 mm mast / tripod holder.

Parameter Value
Frequency range 600 MHz to 6 GHz (usable from 380 MHz)
RF input power, max 250 W (70 W with MNW 400 and MNW 460)
Impedance (nominal) 50 Ω
Typically power requirement 15 to 250 W for 300 V/m at 0.1 m distance (see curve in datasheet)
Field homogeneity 0 to -4 dB
min: 100 cm²
typical: 250 cm²
Max. insertion loss -6 dB
RF input connector N, female
  • IEC/EN 61000-4-39