EM Test PFM 200N Series

Power Fail Module and dropout switch for LV 124/LV 148

Automotive Power Fail Simulator for OEM LV 124 and LV 148 and other manufacturer standards

Highlights

  • Switch for Power supply (100 A / 200 A) and signal/data lines (2 A)
  • Pulses E10 and E13 of the LV 124/LV 148 standard
  • Bidirectional current direction
  • Separate switch in the ground line
  • Rise/fall time less than 200ns
  • Built in short-circuit switch <100 mohm
  • Rated voltage ±100 VDC
  • short-circuit-proof

Quick Enquiry

If you want to know more about EM Test PFM 200N Series
Power Fail Module and dropout switch for LV 124/LV 148

EM Test Automotive Power Fail Simulator for OEM LV 124 and LV 148 and other manufacturer standards

The PFM 200N100.1 and PFM 200N200 have been designed to fully meet the requirements for E10, E13 and E14 of the LV 124 and the E48-09 of the LV 148. It also allows to perform microinterruptions with fast rise/fall time of as low as 200ns as required by GMW 3172, sec. 9.2.18.

The PFM 200N series includes a switch for the power supply line from 100 mA to 200A and a separate switch in the ground return path. These switches can support very high inrush currents up to several hundreds of Ampères. For signal- and data lines an additional 16 channel switch is included with current rating from 100 uA to 2 A per channel

  • BMW GS 95003-2
  • BMW GS 95024-2-1
  • BMW GS 95026
  • BMW QV 65013 (2010-06)
  • Chrysler CS-11979
  • Chrysler PF-9326
  • Cummins 14269 (982022-026)
  • DaimlerChrysler DC-10615
  • DaimlerChrysler DC-10842
  • Fiat 9.90110
  • GMW 3172
  • Hyundai/Kia ES 95400-10, Rev. D
  • Hyundai ES 39110-00
  • Iveco 16-2103 Rev.15 (2010)
  • LV 123
  • LV 148
  • BN 10615
  • MBN LV 124-1
  • Nissan 28401 NDS 02
  • OEM LV 124
  • OEM LV 124 (2013-02)
  • OEM LV 148
  • PSA B21 7110
  • Renault 36.00.808/–L
  • Tata TST/TS/WI/257
  • Toyota TSC3500G
  • Toyota TSC3590G
  • Toyota TSC6203G
  • Toyota TSC7203G
  • Volvo STD 515-0003
  • VW 80000
  • VW 82148
  • and many other automotive standards

Calibration Set for OEM LV 124, LV148 and related Standards

The CA LV sets include four load resistors for the verification of the pulses, for example E10 and E13 of the LV 124 (2013). The load resistors CA LV124-P1R and CA LV124-P100R are used for power line verification.

For verification the 16 signal and data lines the CA LV124-D1R and CA LV124-D1000R are used.

PFM 200N series Datasheet 