CISPR 16-2-1’s most recent edition 3.0 specifies a new test method which allows the use of a coupling/decoupling network for emission measurement (CDNE) to measure disturbance voltages in the 30 to 300 MHz frequency range. This method enables EUTs to be connected directly to the CDNE, allowing a single conducted emission measurement to replace a lengthy radiated emission test. Product standards may use this fast, convenient and economical alternative.
CISPR 15 offers an independent method for measurement of radio disturbance characteristics of electrical lighting equipment. This method specifies the use of a coupling/decoupling network (CDN) as defined in IEC 61000-4-6 with an extended frequency range 30 to 300 MHz. Using a CDNE as described in CISPR 16-1-2 instead of CDN offers improved measurement reproducibility due to standard’s requirements for more restrictive limits of asymmetrical impedance, phase angle, symmetrical impedance and internal attenuation.
The Teseq CDNEs are compliant with the actual versions of CSIPR 16-1-2, CISPR 16-2-1 and CISPR 15’s CDN method.
Parameter | Value |
---|---|
Frequency range | 30 to 300 MHz |
Power rating (EUT- and AE port) | AC max. voltage (line to line) for CDNE M210, CDNE M310: 520 V AC max. voltage (line to line) for CDNE M310-USJP: 125 V DC max. voltage for CDNE M210, CDNE M310: 300 V DC max. voltage for CDNE M310-USJP: 125 V (US/JP socket) |
Current max | 10 A |
Mains sockets (EUT- and AE port) | 4 mm, safety banana |
Mains sockets (EUT- and AE port) for CDNE M310-USJP | NEMA 5-15/IEC C14 |
Common mode impedance (EUT port) | 150 Ω +10/-20 Ω |
Phase angle (EUT port) | 0° ±25° |
Differential mode impedance (EUT port) | 100 Ω ±20 Ω |
Common mode impedance (EUT port) | 150 Ω +10/-20 Ω |
Transducer factor/Voltage division factor (EUT/RF port) incl. internal 10 dB attenuator: | 20 dB ±1.5 dB |