Teseq FT 801

Decoupling Ferrite tube

FT 801 Ferrite tube

  • Conform with IEC 61000-4-6 ed. 4
  • Excellent decoupling from 150 kHz
  • Simple insertion in the test setup
  • Large diameter of 35 mm

Quick Enquiry

If you want to know more about Teseq FT 801
Decoupling Ferrite tube

The FT 801 is recommended as an additional decoupling network (ferrite tube) for immunity test according to IEC / EN 61000-4-6 when using the clamp injection method. It shall be inserted on all the cables between EUT and AE except the cable under test. The FT 801 prevents, that the test signal applied to the EUT affects other devices, equipment or systems, which are not under test and improves the reproducibility of the test results.
The large inner diameter of the FT 801 allows threading of cables with connectors.

Parameter Value
Frequency range 150 kHz to 1000 MHz
Insertion loss as given in the graph
Maximum cable diameter 35 mm
Dimension (LxWxH) 670 mm x 70 mm x 80 mm
Weight approx. 8 kg
  • IEC/EN 61000-4-6
  • CISPR 24
  • EN 61000-6-1
  • EN 61000-6-2
  • IEC 60533
  • IEC 60601-1-2
  • IEC 61326

FT 801 Ferrite tube Datasheet