Reproducible emissions measurements require a defined line termination for the frequency range where connected lines provide a significant influence on the emissions. The key parameter is the asymmetrical impedance (common-mode impedance) which can be seen as the common mode impedance to the reference ground.
Parameter | Value |
---|---|
Frequency range as required in CISPR 16-1-4 | 30 MHz to 200 MHz |
Frequency range for general use | 1 MHz to 1000 MHz |
Maximum cable diameter | 20 mm |
Dimension (LxWxH) | 670 mm x 78 mm x 58 mm |
Weight | approx. 3.4 kg |