Search

FCC Bulk Current Injection (BCI) Probes

Bulk Current Injection Probes & Calibration fixtures

Quick Enquiry

If you want to know more about FCC Bulk Current Injection (BCI) Probes

Fischer Custom Communications, Inc. develops and manufactures Bulk Current Injection Probes to meet specific customer and compliance testing requirements. Fischer Custom Communications, Inc. Bulk Current Injection Probes are used for compliance testing in accordance with Mil-Std-461/462, RTCA/DO-160 Section 20 and 22, Bellcore TR-NWT-001 089, SAE Jl5447, EN 55101-4 and CSEFA-2 Euro-Fighter and other susceptibility specifications.

BCI Probes

Selection guide  

Product
Usable Frequency
Rated Watts
(CW)
High-Efficiency
Bandpass Insertion Loss / Freq
Inner Diam
(mm)
Outer Diam
(mm)
Height
(mm)
Calibration Fixture

F-120-5

10kHz – 100MHz 100 <10dB/500kHz – 1MHz 65 142 53 FCC-BCICF-3

F-120-6A

10kHz – 400MHz 100 <7dB/700kHz – 200MHz 40 127 70 FCC-BCICF-1

F-120-7B

10kHz – 400MHz 125 <10dB / 1MHz – 400MHz 65 142 54 FCC-BCICF-3

F-120-8

10kHz – 400MHz 200 <7dB/800kHz – 300MHz 40 127 134 *, F-170421-1008-1, FCC-BCICF-4

F-120-8-HV

10kHz – 400MHz 5kV Peak Pulse <5dB / 1MHz – 400MHz 40 127 134 FCC-BCICF-4-HV

F-120-8F

10kHz – 400MHz 250 <5dB / 500kHz – 200MHz 40 127 134 *, F-170421-1008-1, FCC-BCICF-4

F-120-9

10kHz – 230MHz 100 <11dB/150kHz – 230MHz 40 127 70 FCC-BCICF-1

F-120-9A

10kHz – 230MHz 125 <8dB/150kHz – 100MHz 40 127 134 FCC-BCICF-4

F-130-3

1MHz – 400MHz 100 <7dB/3MHz – 200MHz 65 142 54 FCC-BCICF-3

F-130A-1

1MHz – 400MHz 100 <7dB/3MHz – 350MHz 40 127 70 FCC-BCICF-1

F-140

1MHz – 1GHz 100 <7dB/2MHz – 170MHz 40 127 70 FCC-BCICF-2

F-140-HV

100kHz – 400MHz 5kV Peak Pulse <7dB / 2MHz – 300MHz 40 127 70 FCC-BCICF-1-HV

F-150

800MHz – 2.1GHz 250 <7dB/950MHz – 2.0GHz 32 98 38 FCC-BCICF-150

F-150-1

2.3GHz – 7.0GHz 100 <9dB/2.3GHz – 7GHz 12 33 13 FCC-BCICF-150-1

F-150-2

800MHz – 2.1GHz 250 <9dB / 800MHz – 2.1 GHz 40 98 38 FCC-BCICF-150-2

F-070601-1008-1

400MHz – 1GHz 250 <7dB/450MHz – 1GHz 40 127 70 F-070601-1008-2

F-080409-1008-1

2.0 GHz – 3GHz 100 <9dB / 2GHz – 3.0GHz 32 71 19 F-080409-1008-2

F-080728-1008-1

500MHz – 1GHz 250 <7dB/500MHz – 800MHz 65 142 54 F-080728-1008-2

F-080915-1008-1

3GHz – 4GHz 100 <8dB / 3.2GHz – 3.9GHz 32 53 10 F-080915-1008-2

F-120501-1008-1

1kHz – 10MHz 1000 <9dB / 500kHz – 10MHz 40 x 91 152 x 286 191 F-120501-1008-2

F-161012-1008-1

10kHz – 10MHz 2500 <7dB / 200kHz – 10MHz 54 x 108 203 x 305 241 F-161012-1008-2

F-170501-1008-1

10MHz – 400MHz 2500 <7dB / 10MHz – 400MHz 40 127 134 F-170421-1008-1

F-170701-1008-1

10MHz – 400MHz 1000 <8dB / 10MHz – 400MHz 40 127 70 FCC-BCICF-1

Bulk Current Calibration Fixture Guide

Using BCI Probes for upset investigation